Unblinking Eye

Traditional darkroom photography and historical photographic processes

Articles on photography

FW’s Recommendations for Kodak T-Max 100

About 2 minutes to read.

Developer

Dilution

Exposure

Time

Temperature

E.I.
Rodinal 1:50 N-2 9 m 20° C 32
Rodinal 1:50 N-1 10.5 m 20° C 50
Rodinal 1:50 N 13 m 20° C 80
Rodinal  1:50 N+1 18 m 20° C 125
Rodinal  1:50 N+2 21 m 20° C 160
Comments:  I find that TMax100 responds best in Rodinal rather than in one of the  staining developers, so here is the table I use, based on 4x5 sheets in  Rodinal 1:50 @ 20C in a combi-tank.  Agitation is constant for the first minute, and then for 10s every 30s  thereafter. I then just rinse with clean water for about 60 - 90s, and fix  for 10 minutes. Rodinal takes most of the magenta anti-halation dye out  anyway.

John Hicks’ Recommendations for Kodak T-Max 100

Developer

Dilution

Time

Temperature

E.I.
D-76H 1:3 13 m 15 s 75° F 100
TFX-2 Straight 13 m 15 s 68° F 100
Rodinal 1:100 11 m 68° F 100
Comments:  All intermittent inversion agitation.  [D-76H omits the hydroquinone and increases the metol to 2.5 grams.]

Ed Buffaloe’s Recommendations for Kodak T-Max 100

Developer

Dilution

Time

Temperature

E.I.
PMK 1:2:100 13 m 70° F 64
PMK+ 1:2:100 13 m 70° F 100
Rodinal 1:75 10 m 70° F 50
Rodinal 1:75 15 m 70° F 80
FX-4 1:1 8.5 m 70° F 100
T-Max 1:4 6.5 m 75° F 50
Comments:  These times are for roll films in small tanks, optimized for a diffusion enlarger.  For PMK and PMK+, agitation is for first 30 seconds, then 5 seconds each 30 seconds thereafter.  For all others, agitation is for first 30 seconds, then 10 seconds each minute thereafter.

        FX-4
        Water (125 F or 52  C) -                      750.0 ml
        Metol                                                       1.5 grams
        Hydroquinone                                       6.0 grams
        Phenidone                                            0.25 grams
        Sodium Sulfite, anhydrous -            100.0 grams
        Borax                                                       2.5 grams
        Potassium Bromide -                             0.5 grams
        Add cold water to make -                     1.0 liter
        This developer is G.W. Crawley’s answer to D-76,
        giving greater speed and more compensation.

Greg Gallagher’s Recommendations for Kodak T-Max 100

Developer

Dilution

Exposure

Time

Temperature

E.I.
HC-110 B N 6.5 m 20° C 50
Beutler 105 1:1:8 N-1 6.75 m 20° C 50
Beutler 105 1:1:8 N 8 m 20° C 50
Beutler 105 1:1:8 N+1 11.75 m 20° C 50
Comments:  Agitate for first minute, then 10 seconds per minute thereafter.  I realize the HC110 procedure is somewhat textbook, but I found it to work rather well.

                                 Beutler 105
            Solution A
            Water (125 F/ 52 C)             750 ml
            Metol                                   10.0 grams
            Sodium Sulfite                    50.0 grams
            Water to make                       1.0 liter
             
            Solution B
            Water (125F/ 52C)                750 ml
            Sodium Carbonate(anyh)   50.0 grams
            Water to make                        1.0 liter
             
            Mix 1 part "A", 1 part "B", and 8 parts water

Trevor Crone’s Recommendation for Kodak T-Max 100

Developer

Dilution

Time

Temperature

E.I.
DiXactol Single Solution 7.5 m 21° C 80
Comments:  Superb gradation and sharpness. Also responds well to N-/N+.

Chris’ Recommendations for Kodak T-Max 100

Developer

Dilution

Exposure

Time

Temperature

E.I.
HC-110 1:11 N-2 6 m 68° F 25
HC-110 1:11 N-1 7.5 m 68° F 25
HC-110 1:11 N 9 m 68° F 25
HC-110 1:11 N+1 10.5 m 68° F 25
HC-110 1:11 N+2 12 m 68° F 25
Comments: I use HC-110 diluted out to 1:11 from the stock solution. This is instead of something normal like Dil. B at 1:7. I use old hard rubber tanks and hangers, with first 30 second agitation, then 5 seconds at each minute.  I suspect my plus/minus changes are not real accurate, but I have a good feeling for how much change that is in practical situations.  I do expose the TMX at 25, however, which I think part of is my meter, but it is consistent at least.